01

The frame colour is the easy choice

Most window decisions are made in a showroom: white or dark grey, timber or uPVC, casement or sash. Those choices matter for how the house looks. They say almost nothing about whether the room behind the glass will be cold in winter, hot in the afternoon or wet on the sill each morning.

That information sits on a label. In the United States it is the label of the National Fenestration Rating Council, a non-profit body that sponsors certified rating and labelling. ENERGY STAR explains on its ratings page that every certified window must be independently tested and verified to NFRC procedures, and that the NFRC itself does not set minimum standards or call any window good or bad. The label gives you numbers. Deciding which numbers suit your house is your job and your designer’s, and it starts with the climate, as the note on designing for climate argues.

02

U-factor: how fast heat leaks through

The first number measures how quickly heat moves through the window. Lower is better at keeping heat where you want it. The US Department of Energy’s purchasing guidance says US ratings are given in Btu per hour per square foot per degree Fahrenheit, and typically range between 0.2 and 1.2.

The detail that catches buyers is what the number covers. The NFRC method rates the whole window, including frame and spacers. A centre-of-glass figure describes the glazing alone, and the Department of Energy’s window guideline notes that for most efficient windows the whole-window figure is the worse of the two. A brochure that quotes only the glass is quoting its best side.

What brings the number down is well established: two or more panes, low-emittance coatings, argon or krypton in the gap, and frames of wood, vinyl or fibreglass. Metal frames need properly designed thermal breaks. The same guideline says standard thermal breaks have cut aluminium frame U-factors from roughly 2.0 to about 1.0 in US units, which is why an aluminium window without one sits in a different class.

Cut section of a laminated timber window frame holding a sealed double-glazed unit with its edge spacer
A cut-away timber frame with a sealed glazing unit. The whole-window rating counts the frame and the spacer at the glass edge, not just the glass.
Photograph: Kozuch · CC BY-SA 3.0. Source and licence.
03

SHGC: the sun you pay for, or the sun you want

The second number, the solar heat gain coefficient, is the share of the sun’s heat that gets through, on a scale from 0 to 1. The Department of Energy puts real products between about 0.20 and 0.80, and splits low-e glass into types: low gain, below 0.4, for hot climates, and high gain, above 0.55, for cold ones, where winter sun is free heating.

This is where a window bought for the wrong climate does damage. Low solar gain glass on the sunny side of a living room in a cold country throws away useful warmth; high gain glass on a west wall in the tropics can turn the room into an oven by late afternoon. The Department of Energy does not recommend tinting for homes because it spoils the view, and points to overhangs, external screens and blinds instead, the same shading logic in the note on energy-efficient design.

A third figure keeps that honest. Visible transmittance measures daylight rather than heat. Higher values let in more light, and the same guidance says values below 0.5 noticeably cut it, so when you pick a low solar gain window, check you have not also bought a dim room.

04

Air leakage and condensation, the smaller print

Two more ratings may appear. Air leakage is measured in cubic feet of air per minute through each square foot of window, and ENERGY STAR notes that most industry standards and building codes require 0.3 or less. Condensation resistance is scored from 0 to 100; the higher the score, the less moisture builds up on the inside. The Department of Energy guideline lists condensation resistance as optional on the NFRC label, so ask for it if it is missing.

Condensation usually starts at the edge. The Department of Energy guideline explains that traditional aluminium spacers between the panes act as a thermal short circuit, and that the bottom edge of the window carries the highest risk of condensation. Warm edge spacers, made from less conductive materials, address this, and the guideline reported in 2012 that they were already used in more than 90 percent of new windows. Wet glass every morning can also mean the house holds too much moisture, which is a ventilation question as much as a window one; the note on insulation and ventilation covers that side.

Droplets of condensation covering the inside of a window pane
Condensation on the inside of a window. It forms first where the glass and frame are coldest, often along the bottom edge.
Photograph: Doggo19292 · Public domain. Source and licence.
05

Same idea, different units

Outside the United States, U-values are usually given in watts per square metre per kelvin, and the numbers look about five and a half times larger: one US unit equals roughly 5.68 metric ones. Compare like with like before you decide one supplier is far ahead of another.

England’s Approved Document L, 2021 edition incorporating the 2023 amendments, shows how a building code uses the figure. It says a window’s U-value is assessed for the whole unit, glazing and frame combined. For a new home, the limiting value for windows is 1.6 W/(m²·K). For a new or replacement window in an existing home, it is 1.4, or a Window Energy Rating of Band B, and a replacement must also be no worse than the window it replaces. Where windows cannot meet that because the character of the building must be kept, the document allows glazing with a centre pane U-value no higher than 1.2, or low-emissivity secondary glazing behind single glazing. That matters if you are renovating an older house.

A semi-detached brick house in England under scaffolding while its old windows are taken out and stacked by the road
Windows being replaced on a house in England. There, a replacement must be no worse than the old window and meet the current limit.
Photograph: John Sutton · CC BY-SA 2.0. Source and licence.
06

A good window badly fitted is a leak

The label rates the product, not the hole in your wall. The Department of Energy guideline lists the basics of installation: set the unit level, plumb and square; keep the weather-resistant barrier of the wall continuous; and fill voids between frame and wall with low-expansion foam or caulk with a backer rod, never fibrous insulation, which lets air through. It says sill pan flashings are always recommended, and describes a common sequence of sill flashing first, then the jambs, then the window, then the head flashing over the top, so every layer sheds water outwards. It also tells installers to follow the manufacturer’s instructions rather than general rules.

Openings are where water most often gets into a wall, which is why the note on keeping water out treats every window as a junction. The Department of Energy’s advice for contracts is simple: specify the U-factor and SHGC. Put both, as whole-window figures, into the quote, and when you compare quotes, check that each supplier priced the same window and the same fitting details.

Do

  • Ask for whole-window U-value and SHGC figures for each window type, in writing.
  • Pick solar gain to suit the climate and the wall the window faces.
  • Ask how the sill, jambs and head will be flashed and sealed.

Avoid

  • Compare a centre-of-glass figure from one supplier with a whole-window figure from another.
  • Mix US and metric U-values without converting them.
  • Fill the gap around a frame with fibrous insulation.

Sources & scope

Sources reviewed 27 November 2026. The NFRC ratings, ENERGY STAR notes and Department of Energy guidance describe practice in the United States, and some figures in the 2012 window guideline may have moved since. The Approved Document L values apply to England; other countries and regions set their own rules or none. The unit conversion is approximate. This is not technical or legal advice: check your local building code and use a qualified designer and installer. The photographs from Britain and the cut-away frame show windows in general, not a recommended product.

Written by 3dspace.mu Editorial. This article is general educational material, not professional review or advice for your site. No claim of architect or engineer authorship is made.